108 research outputs found

    Contributions of cochlea-scaled entropy and consonant-vowel boundaries to prediction of speech intelligibility in noise

    Get PDF
    published_or_final_versio

    A universal two-way approach for estimating unknown frequencies for unknown number of sinusoids in a signal based on eigenspace analysis of Hankel matrix

    Get PDF
    YesWe develop a novel approach to estimate the n unknown constituent frequencies of a noiseless signal that comprises of unknown number, n, of sinusoids of unknown phases and unknown amplitudes. The new two way approach uses two constraints to accurately estimate the unknown frequencies of the sinusoidal components in a signal. The new approach serves as a verification test for the estimated unknown frequencies through the estimated count of the unknown number of frequencies. The Hankel matrix, of the time domain samples of the signal, is used as a basis for further analysis in the Pisarenko harmonic decomposition. The new constraints, the Existence Factor (EF) and the Component Factor (CF), have been introduced in the methodology based on the relationships between the components of the sinusoidal signal and the eigenspace of the Hankel matrix. The performance of the developed approach has been tested to correctly estimate any number of frequencies within a signal with or without a fixed unknown bias. The method has also been tested to accurately estimate the very closely spaced low frequencies.Innovate U

    Sensitivity of the human auditory cortex to acoustic degradation of speech and non-speech sounds

    Get PDF
    The perception of speech is usually an effortless and reliable process even in highly adverse listening conditions. In addition to external sound sources, the intelligibility of speech can be reduced by degradation of the structure of speech signal itself, for example by digital compression of sound. This kind of distortion may be even more detrimental to speech intelligibility than external distortion, given that the auditory system will not be able to utilize sound source-specific acoustic features, such as spatial location, to separate the distortion from the speech signal. The perceptual consequences of acoustic distortions on speech intelligibility have been extensively studied. However, the cortical mechanisms of speech perception in adverse listening conditions are not well known at present, particularly in situations where the speech signal itself is distorted. The aim of this thesis was to investigate the cortical mechanisms underlying speech perception in conditions where speech is less intelligible due to external distortion or as a result of digital compression. In the studies of this thesis, the intelligibility of speech was varied either by digital compression or addition of stochastic noise. Cortical activity related to the speech stimuli was measured using magnetoencephalography (MEG). The results indicated that degradation of speech sounds by digital compression enhanced the evoked responses originating from the auditory cortex, whereas addition of stochastic noise did not modulate the cortical responses. Furthermore, it was shown that if the distortion was presented continuously in the background, the transient activity of auditory cortex was delayed. On the perceptual level, digital compression reduced the comprehensibility of speech more than additive stochastic noise. In addition, it was also demonstrated that prior knowledge of speech content enhanced the intelligibility of distorted speech substantially, and this perceptual change was associated with an increase in cortical activity within several regions adjacent to auditory cortex. In conclusion, the results of this thesis show that the auditory cortex is very sensitive to the acoustic features of the distortion, while at later processing stages, several cortical areas reflect the intelligibility of speech. These findings suggest that the auditory system rapidly adapts to the variability of the auditory environment, and can efficiently utilize previous knowledge of speech content in deciphering acoustically degraded speech signals.Puheen havaitseminen on useimmiten vaivatonta ja luotettavaa myös erittäin huonoissa kuunteluolosuhteissa. Puheen ymmärrettävyys voi kuitenkin heikentyä ympäristön häiriölähteiden lisäksi myös silloin, kun puhesignaalin rakennetta muutetaan esimerkiksi pakkaamalla digitaalista ääntä. Tällainen häiriö voi heikentää ymmärrettävyyttä jopa ulkoisia häiriöitä voimakkaammin, koska kuulojärjestelmä ei pysty hyödyntämään äänilähteen ominaisuuksia, kuten äänen tulosuuntaa, häiriön erottelemisessa puheesta. Akustisten häiriöiden vaikutuksia puheen havaitsemiseen on tutkttu laajalti, mutta havaitsemiseen liittyvät aivomekanismit tunnetaan edelleen melko puutteelisesti etenkin tilanteissa, joissa itse puhesignaali on laadultaan heikentynyt. Tämän väitöskirjan tavoitteena oli tutkia puheen havaitsemisen aivomekanismeja tilanteissa, joissa puhesignaali on vaikeammin ymmärrettävissä joko ulkoisen äänilähteen tai digitaalisen pakkauksen vuoksi. Väitöskirjan neljässä osatutkimuksessa lyhyiden puheäänien ja jatkuvan puheen ymmärrettävyyttä muokattiin joko digitaalisen pakkauksen kautta tai lisäämällä puhesignaaliin satunnaiskohinaa. Puheärsykkeisiin liittyvää aivotoimintaa tutkittiin magnetoenkefalografia-mittauksilla. Tutkimuksissa havaittiin, että kuuloaivokuorella syntyneet herätevasteet voimistuivat, kun puheääntä pakattiin digitaalisesti. Sen sijaan puheääniin lisätty satunnaiskohina ei vaikuttanut herätevasteisiin. Edelleen, mikäli puheäänien taustalla esitettiin jatkuvaa häiriötä, kuuloaivokuoren aktivoituminen viivästyi häiriön intensiteetin kasvaessa. Kuuntelukokeissa havaittiin, että digitaalinen pakkaus heikentää puheäänien ymmärrettävyyttä voimakkaammin kuin satunnaiskohina. Lisäksi osoitettiin, että aiempi tieto puheen sisällöstä paransi merkittävästi häiriöisen puheen ymmärrettävyyttä, mikä heijastui aivotoimintaan kuuloaivokuoren viereisillä aivoalueilla siten, että ymmärrettävä puhe aiheutti suuremman aktivaation kuin heikosti ymmärrettävä puhe. Väitöskirjan tulokset osoittavat, että kuuloaivokuori on erittäin herkkä puheäänien akustisille häiriöille, ja myöhemmissä prosessoinnin vaiheissa useat kuuloaivokuoren viereiset aivoalueet heijastavat puheen ymmärrettävyyttä. Tulosten mukaan voi olettaa, että kuulojärjestelmä mukautuu nopeasti ääniympäristön vaihteluihin muun muassa hyödyntämällä aiempaa tietoa puheen sisällöstä tulkitessaan häiriöistä puhesignaalia

    The Sound Sensation of Apical Electric Stimulation in Cochlear Implant Recipients with Contralateral Residual Hearing

    Get PDF
    BACKGROUND: Studies using vocoders as acoustic simulators of cochlear implants have generally focused on simulation of speech understanding, gender recognition, or music appreciation. The aim of the present experiment was to study the auditory sensation perceived by cochlear implant (CI) recipients with steady electrical stimulation on the most-apical electrode. METHODOLOGY/PRINCIPAL FINDINGS: Five unilateral CI users with contralateral residual hearing were asked to vary the parameters of an acoustic signal played to the non-implanted ear, in order to match its sensation to that of the electric stimulus. They also provided a rating of similarity between each acoustic sound they selected and the electric stimulus. On average across subjects, the sound rated as most similar was a complex signal with a concentration of energy around 523 Hz. This sound was inharmonic in 3 out of 5 subjects with a moderate, progressive increase in the spacing between the frequency components. CONCLUSIONS/SIGNIFICANCE: For these subjects, the sound sensation created by steady electric stimulation on the most-apical electrode was neither a white noise nor a pure tone, but a complex signal with a progressive increase in the spacing between the frequency components in 3 out of 5 subjects. Knowing whether the inharmonic nature of the sound was related to the fact that the non-implanted ear was impaired has to be explored in single-sided deafened patients with a contralateral CI. These results may be used in the future to better understand peripheral and central auditory processing in relation to cochlear implants

    Unanesthetized Auditory Cortex Exhibits Multiple Codes for Gaps in Cochlear Implant Pulse Trains

    Get PDF
    Cochlear implant listeners receive auditory stimulation through amplitude-modulated electric pulse trains. Auditory nerve studies in animals demonstrate qualitatively different patterns of firing elicited by low versus high pulse rates, suggesting that stimulus pulse rate might influence the transmission of temporal information through the auditory pathway. We tested in awake guinea pigs the temporal acuity of auditory cortical neurons for gaps in cochlear implant pulse trains. Consistent with results using anesthetized conditions, temporal acuity improved with increasing pulse rates. Unlike the anesthetized condition, however, cortical neurons responded in the awake state to multiple distinct features of the gap-containing pulse trains, with the dominant features varying with stimulus pulse rate. Responses to the onset of the trailing pulse train (Trail-ON) provided the most sensitive gap detection at 1,017 and 4,069 pulse-per-second (pps) rates, particularly for short (25 ms) leading pulse trains. In contrast, under conditions of 254 pps rate and long (200 ms) leading pulse trains, a sizeable fraction of units demonstrated greater temporal acuity in the form of robust responses to the offsets of the leading pulse train (Lead-OFF). Finally, TONIC responses exhibited decrements in firing rate during gaps, but were rarely the most sensitive feature. Unlike results from anesthetized conditions, temporal acuity of the most sensitive units was nearly as sharp for brief as for long leading bursts. The differences in stimulus coding across pulse rates likely originate from pulse rate-dependent variations in adaptation in the auditory nerve. Two marked differences from responses to acoustic stimulation were: first, Trail-ON responses to 4,069 pps trains encoded substantially shorter gaps than have been observed with acoustic stimuli; and second, the Lead-OFF gap coding seen for <15 ms gaps in 254 pps stimuli is not seen in responses to sounds. The current results may help to explain why moderate pulse rates around 1,000 pps are favored by many cochlear implant listeners

    Evaluations on underdetermined blind source separation in adverse environments using time-frequency masking

    Get PDF
    The successful implementation of speech processing systems in the real world depends on its ability to handle adverse acoustic conditions with undesirable factors such as room reverberation and background noise. In this study, an extension to the established multiple sensors degenerate unmixing estimation technique (MENUET) algorithm for blind source separation is proposed based on the fuzzy c-means clustering to yield improvements in separation ability for underdetermined situations using a nonlinear microphone array. However, rather than test the blind source separation ability solely on reverberant conditions, this paper extends this to include a variety of simulated and real-world noisy environments. Results reported encouraging separation ability and improved perceptual quality of the separated sources for such adverse conditions. Not only does this establish this proposed methodology as a credible improvement to the system, but also implies further applicability in areas such as noise suppression in adverse acoustic environments

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    See Hear: Psychological Effects of Music and Music-Video During Treadmill Running

    Get PDF
    © 2014, The Society of Behavioral Medicine.Background: There is a paucity of work addressing the distractive, affect-enhancing, and motivational influences of music and video in combination during exercise. Purpose: We examined the effects of music and music-and-video on a range of psychological and psychophysical variables during treadmill running at intensities above and below ventilatory threshold (VT). Methods: Participants (N = 24) exercised at 10 % of maximal capacity below VT and 10 % above under music-only, music-and-video, and control conditions. Results: There was a condition × intensity × time interaction for perceived activation and state motivation, and an intensity × time interaction for state attention, perceived exertion (RPE), and affective valence. The music-and-video condition elicited the highest levels of dissociation, lowest RPE, and most positive affective responses regardless of exercise intensity. Conclusions: Attentional manipulations influence psychological and psychophysical variables at exercise intensities above and below VT, and this effect is enhanced by the combined presentation of auditory and visual stimuli
    corecore